<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Rafsanjan University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی رفسنجان</title_fa>
<short_title>JRUMS</short_title>
<subject>Medical Sciences</subject>
<web_url>http://journal.rums.ac.ir</web_url>
<journal_hbi_system_id>69</journal_hbi_system_id>
<journal_hbi_system_user>journal69</journal_hbi_system_user>
<journal_id_issn>1735-3165</journal_id_issn>
<journal_id_issn_online>2008-7268</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.66224/jrums</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>9</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی، ساخت و تعیین روایی و پایایی هدبند دیجیتال ارزیابی حس عمقی گردن:
مطالعه توصیفی</title_fa>
	<title>Designing, Fabricating, and Testing the Validity and Reliability of the Digital Headband for Cervical Proprioception Assessment: A Descriptive Study</title>
	<subject_fa>تربيت بدني</subject_fa>
	<subject>تربيت بدني</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;چکیده&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;زمینه و هدف: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;دقت اطلاعات حس عمقی نقش بسیار مهمی در کنترل حرکات سر و گردن بر عهده دارد. تاکنون از روش&amp;shy;های متعددی به منظور ارزیابی دقت اطلاعات حس عمقی به&amp;shy;عنوان عاملی جهت پیش&amp;shy;گیری از بروز آسیب و یا بازتوانی ناحیه گردنی استفاده شده است. هدف از مطالعه حاضر معرفی ابزاری جدید جهت ارزیابی دقت اطلاعات حس عمقی گردن به همراه تعیین روایی و پایایی آن می&amp;shy;باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;مواد و روش&amp;shy;ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; در این مطالعه توصیفی، تعداد 40 نفر از مردان 60-18 سال بر اساس معیارهای ورود و خروج از تحقیق به&amp;shy;عنوان آزمودنی انتخاب شدند و&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;خطای بازسازی زوایای گردنی آن&amp;shy;ها به وسیله هدبند دیجیتال و دستگاه کروم (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;Cervical Range of Motion; CROM&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;) به&amp;shy;عنوان یک استاندارد طلایی در سنجش زوایای گردنی مورد ارزیابی قرار گرفت. پس از جمع&#8204;آوری اطلاعات مورد نیاز از ضریب همبستگی &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;Pearson&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; به منظور تعیین روایی هم&amp;shy;زمان و از ضریب همبستگی درون&amp;shy;طبقه&#8204;ای (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;Intra-class correlation coefficient; ICC&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;) برای تعیین پایایی درون&amp;shy;آزمونگر و بین&amp;shy;آزمونگر استفاده شد&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;یافته&amp;shy;ها:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; نتایج به&amp;shy;دست آمده از تحقیق حاضر نشان داد که دستگاه هدبند دیجیتال از روایی بسیار بالا (89/0-84/0:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;r&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;)&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;و هم&amp;shy;چنین پایایی درون&amp;shy;آزمونگر و بین&amp;shy;آزمونگر بسیار بالایی (به ترتیب 94/0-89/&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;۰:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;ICC&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; و 93/0-87/&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;۰:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;ICC&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;)&lt;/span&gt;&lt;/span&gt;&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;در ارزیابی دقت حس عمقی گردن برخوردار می&amp;shy;باشد (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;FA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;۰۵/۰&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;P&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;نتیجه&amp;shy;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; دستگاه هدبند دیجیتال به&amp;shy;عنوان یک ابزار دقیق، مقرون به صرفه و با کاربری آسان، اطلاعات مربوط به دقت حس عمقی گردن را در کمترین زمان برای آزمونگر فراهم می&amp;shy;کند و می&amp;shy;تواند جایگزین مناسبی برای سایر روش&amp;shy;های ارزیابی حس عمقی گردن باشد.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;واژه&amp;shy;های کلیدی:&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:11.5pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt; هدبند دیجیتال، حس عمقی، گردن، روایی، پایایی&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:1.0pt&quot;&gt;&lt;span style=&quot;line-height:120%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-size:1.0pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;B Nazanin&amp;quot;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract_fa>
	<abstract>&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:140%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-size:5.0pt&quot;&gt;&lt;span style=&quot;line-height:140%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Background and Objectives:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; Accuracy of proprioceptive input plays an important role in cervical motor control. Several methods have been used to evaluate the accuracy of proprioceptive input as a factor of cervical injury prevention or rehabilitation. The aim of this study was to introduce a new tool for evaluating the accuracy of cervical proprioception and determine its validity and reliability.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Materials and Methods:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; In this descriptive study, 40 men aged 18-60 years were selected as subjects based on inclusion and exclusion criteria, and their cervical repositioning errors were evaluated by using Digital Headband and Cervical Range of Motion (CROM) device as a gold standard in measuring cervical angles. After collecting the required information, Pearson&amp;rsquo;s correlation coefficient and intra-class correlation coefficient (ICC) were used in order to determine the validity and intra-rater and inter-rater reliability, respectively.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Results:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; The results showed that Digital Headband has a very high validity (r: 0.84-0.89) and great intra-rater and inter-rater reliability (ICC: 0.89-0.94 and ICC: 0.87-0.93, respectively) for assessing the accuracy of cervical proprioception (p&lt;0.05).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Conclusion:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; Digital Headband as an accurate, cost-effective, and easy-to-use tool, providing cervical proprioceptive information in the shortest time, can be a good alternative to other methods of cervical proprioception assessment.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Key words:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; Digital Headband, Proprioception, Neck, Validity, Reliability&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;span dir=&quot;RTL&quot; lang=&quot;FA&quot; style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Funding:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; This study was funded by Lorestan University of Medical Sciences.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Conflict of interest: &lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;None&lt;b&gt; &lt;/b&gt;declared.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Ethical approval:&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;span style=&quot;font-size:9.5pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; The&lt;b&gt; &lt;/b&gt;Ethics Committee of Lorestan University of Medical Sciences approved the study (IR.LUMS.REC.1399.386).&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;font-size:10pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;span style=&quot;tab-stops:-45.0pt&quot;&gt;&lt;span style=&quot;text-autospace:none&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Times New Roman&amp;quot;,&amp;quot;serif&amp;quot;&quot;&gt;&lt;b&gt;&lt;span style=&quot;line-height:150%&quot;&gt;How to cite this article:&lt;/span&gt;&lt;/b&gt;&lt;b&gt; &lt;/b&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;Beyranvand Ramin, Hosseini Seyed Mohammad, Mirnasouri Rahim, Abdipour Monfared Mohammad Hossein. Designing, Fabricating, and Testing the Validity and Reliability of the Digital Headband for Cervical Proprioception Assessment: A Descriptive Study&lt;/span&gt;&lt;/span&gt;&lt;span lang=&quot;EN&quot; style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;. &lt;/span&gt;&lt;/span&gt;&lt;i&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;J Rafsanjan&lt;/span&gt;&lt;/span&gt;&lt;/i&gt;&lt;span style=&quot;font-size:9.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt; &lt;i&gt;Univ Med Sci&lt;/i&gt; 2022; 21 (9): 911-22. [Farsi]&lt;/span&gt;&lt;/span&gt;&lt;b&gt; &lt;/b&gt;&lt;b&gt;&lt;span style=&quot;font-size:8.0pt&quot;&gt;&lt;span style=&quot;line-height:150%&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/b&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;</abstract>
	<keyword_fa>هدبند دیجیتال, حس عمقی, گردن, روایی, پایایی</keyword_fa>
	<keyword>Digital Headband, Proprioception, Neck, Validity, Reliability</keyword>
	<start_page>911</start_page>
	<end_page>922</end_page>
	<web_url>http://journal.rums.ac.ir/browse.php?a_code=A-10-3416-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ramin</first_name>
	<middle_name></middle_name>
	<last_name>Beyranvand</last_name>
	<suffix></suffix>
	<first_name_fa>رامین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بیرانوند</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>beyranvand.ra@lu.ac.ir</email>
	<code>6900319475328460051906</code>
	<orcid>6900319475328460051906</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Lorestan University</affiliation>
	<affiliation_fa>دانشگاه لرستان</affiliation_fa>
	 </author>


	<author>
	<first_name>Seyed Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Hosseini</last_name>
	<suffix></suffix>
	<first_name_fa>سید محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حسینی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Physical.education@yahoo.com</email>
	<code>6900319475328460051907</code>
	<orcid>6900319475328460051907</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahid beheshti University</affiliation>
	<affiliation_fa>دانشگاه شهید بهشتی</affiliation_fa>
	 </author>


	<author>
	<first_name>Rahim</first_name>
	<middle_name></middle_name>
	<last_name>Mirnasouri</last_name>
	<suffix></suffix>
	<first_name_fa>رحیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>میرنصوری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Rahim.mirnasouri@yahoo.com</email>
	<code>6900319475328460051908</code>
	<orcid>6900319475328460051908</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Lorestan University</affiliation>
	<affiliation_fa>دانشگاه لرستان</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad Hosein</first_name>
	<middle_name></middle_name>
	<last_name>Abdipour Monfared</last_name>
	<suffix></suffix>
	<first_name_fa>محمد حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عبدی پور منفرد</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mohamadabdi216@gmail.com</email>
	<code>6900319475328460051909</code>
	<orcid>6900319475328460051909</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Technical and Vocational University</affiliation>
	<affiliation_fa>دانشگاه فنی و حرفه ای</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
