Abstract:   (5581 Views)

Background and Objective: Hospital waste water due to infectious organisms and other risk factors is important. In this study, the possibility of coliform bacteria removal from hospital waste water using ozone separately and combining with hydrogen peroxide (H2O2 + O3) as a pre-treatment was investigated.

Material and Methods: This is an experimental study that in the second moiety of 1392 in Kerman University of Medical Sciences and Engineering Research Center for Environmental Health Institute of the East Azerbaijan province was executed. Hospital microbial load in raw waste water,ozone disinfected and advanced oxidized raw sewage was determined by 9-tube most probable number(MPN) method.

Results: Average coliform bacteria and fecal coliform in raw sewage samples from 10 hospitals respectively 3.6×105 and 2.5×105 MPN were calculated. Coliform and fecal coliform removal efficiency of hospital wastewater by ozonation method back in time 10 and 20 minutes respectively (99.79 and 99.91%) and (99.99and 100%). was. Also, removal of coliform and fecal coliform wastewater advanced oxidation hospitals with contact times of 10 and 20 minutes (99.98 and 99.99%) and (100and 100%), respectively.

Conclusion: The trial showed that the effective performance both ozone disinfection and advanced oxidation process (O3 + H2O2) as a pre-treatment is the removal of total coliform bacteria. However, the same results were obtained with a single injection of ozone. It is recommended that the hospital wastewater treatment in order to removal of total coliform bacteria only be done with ozone disinfection.

Key words: Coliform, Advanced oxidation, ozone disinfection, hospital sewage, Removal

 

Funding: This research was funded by Kerman University of Medical Sciences.

Conflict of interest: None declared.

Ethical approval: The Ethical Committee of Kerman University of Medical Sciences, approved the study.

 

How to cite this article:Malakootian M, Dehghanzageh Reyhani R, Sattarvand S, Loloei M. The Effectiveness of Ozone Disinfection and Advanced Oxidation (H2o2 + O3) in the Elimination of Coliform Bacteria from Raw Sewage Hospital. J RafsanjanUniv Med Sci 2015 14(8): 679-90. [Farsi]

Full-Text [PDF 198 kb]   (6426 Downloads) |   |   Full-Text (HTML)  (3806 Views)  
Type of Study: Applicable | Subject: Environmental Health
Received: 2015/01/10 | Accepted: 2015/11/15 | Published: 2015/11/15

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Journal of Rafsanjan University of Medical Sciences

Designed & Developed by : Yektaweb